Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Annals of Surgical Treatment and Research ; : 285-290, 2018.
Article in English | WPRIM | ID: wpr-715169

ABSTRACT

PURPOSE: Among the various energy-based devices, ultrasonic shears are popular in thyroid surgeries. In this study, we tested the safety of Harmonic ACE and Harmonic ACE+ around the recurrent laryngeal nerve (RLN) in experimental swine models. METHODS: Harmonic ACE and Harmonic ACE+ were each tested in 4 piglets. Harmonic ACE and Harmonic ACE+ were activated at a 0- to 5-mm distance from the RLN. The function of the RLN was assessed using continuous electrophysiological monitoring. RESULTS: For Harmonic ACE, there was no adverse EMG event found when activated at 4- and 5-mm distances from the RLN. At a 2- to 3-mm distance, there were 4 adverse EMG events observed. In these 4 cases, adjacent tissue shrinkage occurred after 6 to 15 seconds of activation, and the RLN touched the Harmonic ACE. At a 1-mm distance, there were 2 adverse EMG events found after 25 seconds of activation. For Harmonic ACE+, there was no adverse EMG event observed when activated at 1- and 3-mm distances from the RLN. At a 0-mm distance, 2 adverse EMG events occurred after 6 to 10 seconds of activation. CONCLUSION: The safe distance of Harmonic ACE and ACE+ was 4 and 1 mm, respectively, in the swine models. Harmonic ACE+ is safer than Harmonic ACE because it did not cause any tissue shrinkage. Surgeons need to understand the characteristics of devices for safe operation.


Subject(s)
Recurrent Laryngeal Nerve , Surgeons , Swine , Thyroid Gland , Ultrasonics
2.
Annals of Surgical Treatment and Research ; : 286-296, 2018.
Article in English | WPRIM | ID: wpr-718336

ABSTRACT

PURPOSE: Sentinel lymph node (SLN) biopsy (SLNB) is widely accepted for staging of melanoma patients. It has been shown that clinico-pathological features such as Breslow thickness, ulceration, age, and sex are better predictors of relapse and survival than SLN status alone. The aims of this study were to evaluate the long-term (10-year) prognostic impact of SLNB and to determine predictive factors associated with SLN metastasis, relapse, and melanoma specific mortality (MSM). METHODS: This was a prospective observational study on 289 consecutive patients with primary cutaneous melanoma who underwent SLNB from January 2000 to December 2007, and followed until January 2014, at an Italian academic hospital. RESULTS: SLN was positive in 64 patients (22.1%). The median follow-up was 116 months (79–147 months). Ten-year disease-free survival and melanoma specific survival were poor in patients with positive SLN (58.7% and 66.4%, respectively). Only the increasing Breslow thickness resulted independently associated to an increased risk of SLN metastasis. Cox regression analysis showed that a Breslow thickness >2 mm was an independent predictor of relapse, and male sex and Breslow thickness >2 mm was a predictor of MSM. At 10 years, SLN metastasis was not significantly associated to either relapse or MSM. CONCLUSION: After the fifth year of follow-up, SLN metastasis is not an independent predictive factor of relapse or mortality which are mainly influenced by the characteristics of the primary tumor and of the patient. Patients with a Breslow thickness >2 mm regardless of the SLN status should be considered at high risk for 10-year relapse and mortality.


Subject(s)
Humans , Male , Biopsy , Disease-Free Survival , Follow-Up Studies , Lymph Nodes , Melanoma , Mortality , Neoplasm Metastasis , Observational Study , Prospective Studies , Recurrence , Risk Factors , Sentinel Lymph Node Biopsy , Survival Analysis , Ulcer
3.
Annals of Surgical Treatment and Research ; : 129-134, 2018.
Article in English | WPRIM | ID: wpr-716860

ABSTRACT

PURPOSE: PEAK PlasmaBlade is a recent and distinctive type of electrosurgical device. Previous studies have already documented some meaningful advantages of this device over conventional electrosurgery. This study compared the use of PEAK PlasmaBlade to standard electrosurgery in mastectomy and breast conservative surgery. The purpose was to test the impact of PEAK PlasmaBlade on the wound-healing process and on postsurgical complications in breast cancer surgery. METHODS: Sixty patients undergoing breast cancer surgery were enrolled. The PEAK PlasmaBlade was used for 20 of those. A standard electrosurgical device was used for the other 40 patients. The 2 groups were homogenous in age, body mass index, comorbidities and type of surgery. We recorded wound complications, serum drainage amount and duration of stay, blood loss, time of surgery, length of hospital stay, and total number of medications required. RESULTS: The 2 groups were not significantly different in terms of patient characteristics. A statistically significant reduction in incidence of seroma was observed in the PEAK group: only 10% versus 37.5% of the patients in the conventional electrosurgery group developed this complication (Fisher exact test, P = 0.034). CONCLUSION: Seroma is the most important wound complication in breast surgery. The research of new instruments that might reduce its incidence is desirable. In order to validate or deny the results of this study, it is necessary to enroll more subjects and to consider the impact of this device on axillary lymph node dissection.


Subject(s)
Humans , Body Mass Index , Breast Neoplasms , Breast , Comorbidity , Drainage , Electrosurgery , Equipment and Supplies , Incidence , Intraoperative Complications , Length of Stay , Lymph Node Excision , Mastectomy , Seroma , Surgical Procedures, Operative , Wound Healing , Wound Infection , Wounds and Injuries
4.
Endocrinology and Metabolism ; : 135-136, 2018.
Article in English | WPRIM | ID: wpr-713164

ABSTRACT

No abstract available.


Subject(s)
Korea , Thyroid Gland
5.
Annals of Surgical Treatment and Research ; : 70-75, 2017.
Article in English | WPRIM | ID: wpr-79447

ABSTRACT

PURPOSE: Recently, transoral endoscopic thyroidectomy (TOET) is receiving attention because it is regarded as a true minimally invasive surgery in that it does not leave scars on any part of the body and the area of flap dissection is similar to that of open surgery. In this study, we present the surgical procedures and initial outcomes of TOET in the treatment of papillary thyroid microcarcinoma (PTMC) patients. METHODS: The medical records of patients who underwent TOET for PTMC between July 2016 and February 2017 were retrospectively reviewed. Indication of TOET was PTMC without capsular invasion or lymph node metastasis on preoperative imaging studies. RESULTS: Ten female patients were enrolled. Seven patients underwent thyroid lobectomy and three patients underwent isthmusectomy. The mean age and tumor size was 43.3 ± 11.5 years and 0.6 ± 0.2 cm, respectively. Operation time for lobectomy and isthmusectomy was 121.1 ± 30.7 (range, 65–148) and 90.0 ± 9.2 minutes (range, 82–100 minutes), respectively. The mean number of retrieved lymph nodes was 2.7 ± 1.7. Two patients had transient vocal cord palsy, which recovered in three months. There was no case with subcutaneous emphysema, surgical site infection, postoperative bleeding, or mental nerve injury. CONCLUSION: TOET was feasible and could be performed safely for PTMC. TOET might become a new treatment option for the patients who do not want to leave visible scars on the body.


Subject(s)
Female , Humans , Cicatrix , Hemorrhage , Lymph Nodes , Medical Records , Minimally Invasive Surgical Procedures , Natural Orifice Endoscopic Surgery , Neoplasm Metastasis , Retrospective Studies , Subcutaneous Emphysema , Surgical Wound Infection , Thyroid Gland , Thyroidectomy , Vocal Cord Paralysis
SELECTION OF CITATIONS
SEARCH DETAIL